220V 50HZ Home Heat Pump Heating + Domestic Hot Water 5kw Reted Heating Capacity

220V 50HZ Home Heat Pump Heating + Domestic Hot Water 5kw Reted Heating Capacity

  • 220V 50HZ Home Heat Pump Heating + Domestic Hot Water 5kw Reted Heating Capacity
  • 220V 50HZ Home Heat Pump Heating + Domestic Hot Water 5kw Reted Heating Capacity
  • 220V 50HZ Home Heat Pump Heating + Domestic Hot Water 5kw Reted Heating Capacity
  • 220V 50HZ Home Heat Pump Heating + Domestic Hot Water 5kw Reted Heating Capacity
220V 50HZ Home Heat Pump Heating + Domestic Hot Water 5kw Reted Heating Capacity
Product Details:
Place of Origin: Guangzhou China
Brand Name: Meeting
Certification: CE ISO CCC UKAS,ROHS
Model Number: MD15D
Payment & Shipping Terms:
Minimum Order Quantity: 5 PCS
Price: Negotiation
Packaging Details: Plywooden case
Delivery Time: 15 days
Payment Terms: T/T, L/C WESTERN UNION
Supply Ability: 800/MONTH
Contact Now
Detailed Product Description
Material: Galvanized Sheet Contactor: Fuji Brand
Copper Thick: 1 Mm Compressor: With Oil Heater
Working Temperature: -20--45 Degree Insulation: Foam Pack Pipe And Stick On The Machine Innner
Display: LCD Figer Touch Control: Wifi Function Support
Reted Heating Capacity: 5KW Packing Size: 1200*400*710MM
Refrigerant: R417A Power: 220V/ 50HZ
Noise: 48Db(a) Use: Residential
High Light:

central air heat pump

,

residential geothermal heat pump

Home heat pump Heating + domestic hot water 5kw reted heating capacity

 

Technology Specification

 

 

1.Description :

 

Air source  heat pump is a kind of high energy saving water heater and green products.

In the system, there is a water cycle between indoor unit and outdoor unit. In outdoor unit, there is a refrigerant cycle, we call it reverse Carnot cycle, it consists of four component,

 

 

Feature:

 

1. Economical operation

Generally cost less to operate than other types of conventional heating systems, save your electricity or gas bills.

 

2. Safety

Operate at a high efficiency with no flames, fumes, or flues; Water and electricity isolated

 

3. Environmental friendly

Transfer heat that’s already in the environment; Low CO2 emissions.

 

4. Easy operation

With intelligent control systems which convenient and simple operation

 

5. Constant hot water supply

Provide hot water no matter in cloudy day, snowy day or at night, unlike solar collectors which have to be facing the sun.

 

6. Wide application

Heat pump water heater can be applied to sanitary hot water, house heating .

 

 

Working Principle:

In the system, there is a refrigerant cycle, we call it reverse Carnot cycle, it consists of four component,

Following is air source heat pump working principle.

 

Air source heat pump Working principle picture  

220V 50HZ Home Heat Pump Heating + Domestic Hot Water 5kw Reted Heating Capacity 0

 

 

220V 50HZ Home Heat Pump Heating + Domestic Hot Water 5kw Reted Heating Capacity 1

 

 

 Payment service

1. T/T

2. L/C (for container order only)

 

 

 

FAQ

 

Why us?

1. Timely Delivery, considerate sales after service

 

2. Many Years quality warranty,OEM service.

 

3. Top Craftmanship, All products 100% tested

 

4. Preferential freight by Famous shipping company

 

5. New Design,Very popular style products recommendation for your local market

 

 

Packaging & Shipment

1> Meeting heat pump can sure delivery heat pump within 5~20 working days as we warehouse stock condition.

 

2> Heat pump with strong plywood pallet , strong plywood box for loading, make sure no problem happen during rude transporattion .

 

3> All spare parts of the heat pump water heater will together loading into package , one time finished shipment to buyer.

 

4> Take video of the heat pump for buyer before package to 100% sure buyer get product same as order, no any different.

 

5> Meeting heat pump offer 100% test online, 5% test in Lab by 24 hour for one lot order (if not new model)

Packaging Details :Standard export packing -with plywoods case packages,OEM is available for Factory price heat pump water heaters

Delivery Time :15 work days after arrival of down payment

 

 

 

MODEL Unit MD10D
Rated heating capacity KW 3.5
Rated Cooling capacity   1.8
Hot water supply L/h 75
Average heating input power KW 0.75
Rated heating input current A 6
Rate outlet water temp 55
COP   3.65
Power V/Hz 220V/50
Noise Db(a) 48
Dimension W*D*H mm 1140×360×540
Packing size W*D*H mm 1200*400*710
Unit weight KG 75
Refrigerant   R417A
Working air temp range (-20℃)—45℃
compressor Type   Panasonic
Air source heat exchanger Type   Finned heat exchange
Fan Type   axial flow fan
Hot water side heat exchange Type   Coil heat exchanger
Water flow L/H 1000L/h
Water pressure down Kpa 30
Pipe size DN 20
Max flat square meter M2 29
MODEL Unit MD15D
Rated heating capacity KW 5
Rated Cooling capacity   3
Hot water supply L/h 100
Average heating input power KW 1.25
Rated heating input current A 6
Rate outlet water temp 55
COP   3.65
Power V/Hz 220V/50
Noise Db(a) 48
Dimension W*D*H mm 1140×360×540
Packing size W*D*H mm 1200*400*710
Unit weight KG 75
Refrigerant   R417A
Working air temp range (-20℃)—45℃
compressor Type   Panasonic
Air source heat exchanger Type   Finned heat exchange
Fan Type   axial flow fan
Hot water side heat exchange Type   Coil heat exchanger
Water flow L/H 1600L/h
Water pressure down Kpa 30
Pipe size DN 20
Max flat square meter M2 40
MODEL Unit MD20D
Rated heating capacity KW 7
Rated Cooling capacity   5
Hot water supply L/h 150
Average heating input power KW 1.84
Rated heating input current A 9
Max outlet water temp 60
COP   3.8
Power V/Hz 220V/50
Noise Db(a) 50
Dimension W*D*H mm 1140×360×540
Packing size W*D*H mm 1200*400*710
Unit weight KG 75
Refrigerant   R417A//R410
Working air temp range (-20℃)—45℃
compressor Type   Panasonic
Air source heat exchanger Type   Finned heat exchange
Fan Type   axial flow fan
Hot water side heat exchange Type   Coil heat exchanger
Water flow L/H 2000L/h
Water pressure down Kpa 30
Pipe size DN 20
Max flat square meter M2 55
MODEL Unit MD30D
Rated heating capacity KW 12
Rated Cooling capacity   7
Hot water supply L/h 260
Average heating input power KW 3
Rated heating input current A 13/6
Max outlet water temp 60
COP   4
Power V/Hz 220V/380/50
Noise Db(a) 54
Dimension W*D*H mm 1120*490*710mm
Packing size W*D*H mm 1190*520*865mm
Unit weight KG 108
Refrigerant   R417A/R407C/R404A
Working air temp range   (-20℃)—45℃
compressor Type   Copeland
Air source heat exchanger Type   Finned heat exchange
Fan Type   axial flow fan
Hot water side heat exchange Type   Coil heat exchanger
Water flow L/H 3000L/h
Water pressure down Kpa 40
Pipe size DN 25
Max flat square meter M2 100
MODEL Unit MD40D
Rated heating capacity KW 16
Rated Cooling capacity   10
Hot water supply L/h 360
Average heating input power KW 4
Rated heating input current A 9
Max outlet water temp 60
COP   4.2
Power V/Hz 380V/50
Noise Db(a) 55
Dimension W*D*H mm 1120*490*1270
Packing size W*D*H mm 1200*520*1425
Unit weight KG 160
Refrigerant   R417A/R407C/R404A
Working air temp range   (-20℃)—45℃
compressor Type   Copeland
Air source heat exchanger Type   Finned heat exchange
Fan Type   axial flow fan
Hot water side heat exchange Type   Coil heat exchanger
Water flow L/H 4000L/h
Water pressure down Kpa 45
Pipe size DN 25
Max flat square meter M2 125
MODEL Unit MD50D
Rated heating capacity KW 18
Rated Cooling capacity   12
Hot water supply L/h 400
Average heating input power KW 4.4
Rated heating input current A 9
Max outlet water temp C 60
COP   4.2
Power V/Hz 380V/50
Noise Db(a) 55
Dimension W*D*H mm 1120*490*1270
Packing size W*D*H mm 1200*520*1425
Unit weight KG 160
Refrigerant   R417A/R407C/R404A
Working air temp range   (-20℃)—45℃
compressor Type   Copeland
Air source heat exchanger Type   Finned heat exchange
Fan Type   axial flow fan
Hot water side heat exchange Type   Coil heat exchanger
Water flow L/H 5000L/h
Water pressure down Kpa 45
Pipe size DN 25
Max flat square meter M2 150
MODEL Unit MD60D
Rated heating capacity KW 21
Rated Cooling capacity   15
Hot water supply L/h 520
Average heating input power KW 5.68
Rated heating input current A 12
Max outlet water temp 60
COP   4.2
Power V/Hz 380/50
Noise Db(a) 60
Dimension W*D*H mm 1120*490*1270
Packing size W*D*H mm 1200*520*1425
Unit weight KG 210
Refrigerant   R417A/R407C/R404A
Working air temp range   (-20℃)—45℃
compressor Type   Copeland
Air source heat exchanger Type   Finned heat exchange
Fan Type   axial flow fan
Hot water side heat exchange Type   Coil heat exchanger
Water flow L/H 6000
Water pressure down Kpa 48
Pipe size DN 25
Max flat square meter M2 175
MODEL Unit MD100D
Rated heating capacity KW 36
Rated Cooling capacity   24
Hot water supply L/h 800
Average heating input power KW 9.2
Rated heating input current A 18
Max outlet water temp 60
COP   4.2
Power V/Hz 380V/50
Noise Db(a) 60
Dimension W*D*H mm 1450×760×1060
Packing size W*D*H mm 1520*800*1230
Unit weight KG 289
Refrigerant   R417A/R407C/R404A
Working air temp range   (-20℃)—45℃
compressor Type   Copeland
Air source heat exchanger Type   Finned heat exchange
Fan Type   axial flow fan
Hot water side heat exchange Type   Coil heat exchanger
Water flow L/H 10000L/h
Water pressure down Kpa 54
Pipe size DN 32
Max flat square meter M2 300
MODEL Unit MD150D
Rated heating capacity KW 42
Rated Cooling capacity   29
Hot water supply L/h 1200
Average heating input power KW 11
Rated heating input current A 18
Max outlet water temp 60
COP   4.2
Power V/Hz 380V/50
Noise Db(a) 60
Dimension W*D*H mm 1450×760×1060
Packing size W*D*H mm 1520*800*1230
Unit weight KG 320
Refrigerant   R417A/R407C/R404A
Working air temp range   (-20℃)—45℃
compressor Type   Copeland
Air source heat exchanger Type   Finned heat exchange
Fan Type   axial flow fan
Hot water side heat exchange Type   Coil heat exchanger
Water flow L/H 15000L/h
Water pressure down Kpa 54
Pipe size DN 32
Max flat square meter M2 350
MODEL Unit MD200D
Rated heating capacity KW 72
Rated Cooling capacity   48
Hot water supply L/h 1590
Average heating input power KW 18.2
Rated heating input current A 35
Max outlet water temp 60
COP   4.5
Power V/Hz 380V/50
Noise Db(a) 65
Dimension W*D*H mm 2040×1100×2000
Packing size W*D*H mm 2080×1150×2130
Unit weight KG 650
Refrigerant   R417A/R407C/R404A
Working air temp range   (-20℃)—45℃
compressor Type   Copeland
Air source heat exchanger Type   Finned heat exchange
Fan Type   axial flow fan
Hot water side heat exchange Type   Coil heat exchanger
Water flow L/H 20000L/h
Water pressure down Kpa 60
Pipe size DN 50
Max flat square meter M2 600
MODEL Unit MD300D
Rated heating capacity KW 88
Rated Cooling capacity   65
Hot water supply L/h 24000
Average heating input power KW 25
Rated heating input current A 45
Max outlet water temp 60
COP   4.5
Power V/Hz 380V/50
Noise Db(a) 68
Dimension W*D*H mm 2040×1100×2000
Packing size W*D*H mm 2080×1150×2130
Unit weight KG 650
Refrigerant   R417A/R407C
Working air temp range   (-20℃)—45℃
compressor Type   Copeland
Air source heat exchanger Type   Finned heat exchange
Fan Type   axial flow fan
Hot water side heat exchange Type   Coil heat exchanger
Water flow L/H 30000L/h
Water pressure down Kpa 60
Pipe size DN 50
Max flat square meter M2 730

 

 